Exhaust gases, its concentration in the range, how high the actual treatment efficiency?
Update date:2015-8-12 Browse:1594
Answer:
Take hydrogen sulfide, ammonia and benzene as examples:
1. Moore hydrogen sulfide full light solutions needs 1 Moore of ozone, and the highest ozone concentration produced by our device is about 80ppm in the case of gas flow (meet the requirements of equipment flow rate), that is the highest allowable concentration range of hydrogen sulfide is 80ppm; and ammonia is slightly more complex, the need for more ozone, 1 mol of ammonia at least needs 1.25 mol of ozone, ammonia treatment range is within 64ppm; 1 mol benzene full light solutions needs 5 mol ozone, benzene treatment range is within 15ppm. Therefore, in order to increase the concentration of the intake air, increase the practical application value, the method can be adopted is to increase the power of the device or reduce the intake, so that the cracking of the ozone generates more, cracking more fully. Now our proposal volume for the device has actually reduced many times, for example, now EQ 1. 6KW device (proposal volume5000m3/h), the original proposal volume is1500m3/h. So to be on the safe side, in the device configuration it is possible to configure a large number.